  • Are there any advantages to using Cat 6 cable for computer n
    2017-10-18 15:07:59Are there any advantages to using Cat 6 cable for computer n

    There can be. The introduction of CAT 6 cable was done to meet the specific needs of Gigabit Ethernet. A whole generation of new networking components has been introduced for the purpose of having a Gigabit network. Network Interface Cards,...

  • 2017-10-18 15:00:12More details & technology between network cable

    [Q] Whats the longest ( maximum length ) CAT 5 patch or crossover cable I can buy from you? [A] The maximum length (maximum certifiable length) for CAT 5 patch or crossover cables is 328 feet (100 meters). Beyond that, you run the risk of s...

  • 2017-06-12 16:48:36How to pick the right cables for your home network

    Every so often, we get questions from people who plan to install Ethernet cable in their homes. The most frequent question we get is, whats the difference between Cat 5e and Cat 6 cable, and which should I use? Heres what you need to know ....

  • Nomenclature for WBMMF decided: It’s OM5 fiber
    2017-06-08 10:11:00Nomenclature for WBMMF decided: It’s OM5 fiber

    An International Organization for Standardization/International Electrotechnical Commission (ISO/IEC) standards -making body has decided that the nomenclature used for wideband multimode fiber (WBMMF) will be OM5. The decision was made in O...

  • 2017-06-07 13:46:36Cat5 vs. Cat5e

    Category 5e (Category 5 enhanced) Ethernet cables are newer than category 5 cables and support faster, more reliable data transmission through networks. CAT5 cable is able to transmit data at 10 to 100Mbps speeds, while the newer CAT5e cabl...

  • 2017-06-06 09:59:26Low smoke zero halogen

    Low smoke zero halogen or low smoke free of halogen(LSZHorLSOHorLS0HorLSFHorOHLS) is a material classification typically used for cable jacketing in the wire and cable industry. LSZH cable jacketing is composed of thermoplastic or thermoset...

  • What Kind of Ethernet Lan Cable Should I Use?
    2017-06-05 14:17:20What Kind of Ethernet Lan Cable Should I Use?

    Not all Ethernet cable is created equally. Whats the difference, and how do you know which you should use? Lets look at the technical andphysical differences in Ethernet cable categories to help us decide. Ethernet cables are grouped into s...

  • 2017-06-05 14:16:28The Difference Between CMP and CMR Network Cables

    If you are in need of network cables for Internet or cable TV, you may be a little surprised to see all the different types of cables that are available. Deciding which type you need might be a bit challenging, especially if you are slightl...

  • Coaxial cable assemblies
    2017-06-05 14:16:02Coaxial cable assemblies

    DOCSIS 3.1-compliant jumpers, connectors and cables White Sands Engineering products meet or exceed all current DOCSIS 3.1 standards, the company says, ensuring users have speed and throughput to provide gigabit-speed service throughout a n...

  • What
    2017-06-05 14:07:29What's the Difference Between T568A and T568B?

    A t its January 2016 meeting, the TIAs TR-42.1 Committee agreed to issue for committee ballot the current draft of the TIA-942-B Telecommunications Infrastructure Standard for Data Centers. That ballot was completed in April. A substantial...

  • 2017-06-05 14:05:173 things you’re likely to see in the TIA-942-B data center

    A t its January 2016 meeting, the TIAs TR-42.1 Committee agreed to issue for committee ballot the current draft of the TIA-942-B Telecommunications Infrastructure Standard for Data Centers. That ballot was completed in April. A substantial...

  • 2017-03-30 15:52:35TIA-1152-A Category 8 testing standard approved

    At its October meeting, the TIAs TR-42.7 subcommittee resolved all comments on the ANSI/TIA-1152-A standard and authorized publication of the document. TIA-1152-A covers Category 8 testing in the field. In development since late 2013, the s...

  • 3 things you’re likely to see in the TIA-942-B data center
    2017-03-30 15:44:263 things you’re likely to see in the TIA-942-B data center

    A t its January 2016 meeting, the TIAs TR-42.1 Committee agreed to issue for committee ballot the current draft of the TIA-942-B Telecommunications Infrastructure Standard for Data Centers. That ballot was completed in April. A substantial...

    1. Total 1 Pages 14 records